Data Centre Cooling

/

Room Cooling

/

FreeCool Multi-DENCO®
FreeCool Multi-DENCO®
FreeCool Multi-DENCO®

FläktGroup

FreeCool Multi-DENCO®

Free Cooling for Data Centres, server rooms & small comms rooms.

Overview

Multi-DENCO® close control units with free cooling offer the most energy-efficient solution for air conditioning of server rooms, small data centres, laboratories, technical rooms, or archive rooms that have year-round cooling loads. The devices offer a high level of flexibility, variety, efficiency and are appealing due to their simple planning and installation (plug & play), since all necessary components are factory-installed in the delivery units, i.e., inside the indoor and outdoor devices.

• Systems can operate with 100% free cooling and partial free cooling modes
• Variable speed inverter compressors and electronic expansion valves (EEVs)
• Electrically Commutated (EC) water pumps fitted in the indoor unit
• Small footprint that matches the pure direct expansion range
• Advanced controls package with 4.3" touchscreen provided as standard

Product description

Multi-DENCO® with free cooling is available in two versions:

• F-Version - Indirect free cooling with air-cooled refrigeration circuit
• P-Version - Indirect free cooling with water-cooled refrigeration circuit

F version:

The heat exchanger of the indoor unit consists of two parts: a water-carrying free cooler and a direct expansion evaporator are connected in series in the direction of air flow. The speed-controlled pump for the free cooler and the compressor or compressors for the direct evaporator are fitted inside the indoor unit. The indoor unit is connected to a hybrid condenser/dry cooler as an outdoor unit by means of four lines (flow and return of the free cooling circuit, as well as liquid line and hot gas line of the refrigeration circuit). All components important for the operation are factory-installed in the two delivery units from FläktGroup (plug and play).

P version:

The heat exchanger of the indoor unit consists of two parts: a water-carrying free cooler and a direct expansion evaporator are connected in series in the direction of air flow. The compressor or compressors for the direct evaporator are fitted inside the indoor unit. The water-cooled shell and tube condenser for the refrigeration circuit and the speed-controlled pump for the water circuit are fitted inside a separate substructure delivery unit, which is located directly under the indoor unit. The substructure unit is connected to a dry cooler as an outdoor unit by means of two lines (flow and return of the heat rejection circuit). All components required for operation are factory-installed in the three delivery units from FläktGroup (plug and play).

General advantages:

With the energy saving potential realised by increasing server temperatures according to ASHRAE guideline TC9.9, Multi-DENCO® F- or P-version can take advantage of cold or cooler ambient temperatures to greatly decrease the need for mechanical cooling (i.e. the use of compression refrigeration). The units automatically operate in the most energetically efficient of the 3 different operating modes to minimise the total required energy consumption:

• free cooling,
• compression cooling,
• mixed mode.

These are complete system solutions with the necessary components integrated and minimal installation requirements between the indoor and outdoor units. Both systems work with very efficient inverter compressors, so significant energy savings can be achieved in mixed or part-load operation.

Key facts

• Available as Air Cooled (F-Version) & Water Cooled (P-Version) versions
• F-Version available as upflow and downflow
• P-Version available as downflow only
• Multiple system integration (DENCONet) and Building Management System (BMS) interfaces are available
• Electrically Commutated (EC) fans on both indoor and outdoor units

Features

• Energy Saving: The electricity costs for the operation of the IT cooling are the largest part of the life cycle costs (LCC) of a server room cooling system. The slightly higher investment costs for Multi-DENCO® with free cooling (F- and P-versions) compared to the unit version without free cooling (e.g. A-version) often payback after just one year. In specific customer projects, we have calculated savings of 33% in operating costs. Your FläktGroup sales office will be happy to advise you.
• Hydraulic equipment provided: The Multi-DENCO® F-Version and P-Version both incorporate a variable speed EC pump within the indoor unit - set from the factory to match our system designs. As a designer, it means no time is spent researching, selecting, and matching separate components. Contractors appreciate the immediate operational readiness, allowing for a quick project handover. End-users benefit from savings in operation costs because the device controller controls the pump in every operating state with the energetically optimal speed setting.
• Inverter Compressors: All unit sizes of Multi-DENCO® are equipped with one inverter compressor, two inverter compressors or a combination of one inverter and one on/off compressor (depending on unit size). Using inverter technology, the refrigerant mass flow rate is adapted to the cooling load over a wide working range, so the refrigeration circuit is always operated at the optimum operating point with maximum efficiency. In addition, inefficient fluctuations in the supply air temperature or undershooting the set point are avoided.
• Small Footprint: The installation area is an important criterion in IT rooms. With the Multi-DENCO® F-version, the additional components (e.g., pump) are housed in the indoor unit, with the Multi-DENCO® P-version, the additional components (e.g. pump, shell and tube condenser) are housed in a separate substructure unit, so the required installation area does not increase in each case. Multi-DENCO® outdoor units of the F-version combine a free cooler and condenser in one unit, so that outdoor installation space is also saved.
• Combined Heat Exchangers: Multi-DENCO® indoor units as F- and P-versions are equipped with a combined heat exchanger, which is divided in the air direction into a free cooling circuit using a water-glycol mixture and a direct evaporation circuit with refrigerant. 100% capacity is available in free cooling mode as well as in compression cooling mode or mixed mode. This means that 3 operating modes are available in one device without increasing the space required for the air conditioning equipment in the server room.
• Advanced Controls: Each Multi-DENCO device is equipped with a high-resolution 4.3-inch graphic display. From the home screen there is quick access to device status, temperatures in graphical form and actual and historical alarms. The control system enables an internal network solution (DENCONet) for the optimised and reliable control of several devices in a group, as well as the connection to standard building management systems (BMS). Our C5-12 control platform is designed for installations in even the most critical environments.
• Commissioning Ports: Multi-DENCO® indoor units are equipped with innovative commissioning connections for the refrigeration cycle. These allow commissioning and service technicians quick and easy access at a convenient central location. The connections are located directly behind the front door and allow connection to three different points in the refrigerant circuit for charging and pressure testing.
• Quality Assurance: The aim of server room and data centre cooling is to prevent servers from overheating and thus from being shut down as an emergency protection. Multi-DENCO® was developed based on decades of industry and product experience. FläktGroup produces the product line in three certified factories (ISO 9001, ISO 14001). Only high-quality components from recognised quality brands are used. All devices are tested at the end of the production line by experienced quality inspectors. We offer factory tours and FAT tests (Factory Acceptance Test) - both virtual and in person.