FläktGroup Multi-DENCO® close control units are suitable e.g.

Overview

Multi-DENCO® close control units in the chilled water version (C-version) are suitable for the air conditioning of server rooms, small data centres, laboratories, technical rooms or archive rooms that have year-round air conditioning requirements. The devices offer an elevated level of flexibility, variety and efficiency and are appealing due to high-quality components such as EC fans, powerful heat exchangers and a modern control system.

• 7-unit sizes from 10 kW to 130 kW
• Water-based cooling without refrigerant in the installation room
• Available as CombiCool version with 2 separate water circuits
• Selectable with 2-way, 3-way or pressure-independent 2-way control valves (PICV)
• Highly efficient speed-controlled EC fans

Product description

Multi-DENCO® close control units as chilled water version represents a particularly flexible and future-proof system, since a connection to a wide variety of cooling systems is possible via the chilled water circuit. As a system solution, FläktGroup offers suitable chillers for indoor (FGWC/GLWC) or outdoor installation (FGAC), as well as chillers with an integrated free cooling function (FGFC/GLFC). Furthermore, heat recovery can be realised with the help of 4-pipe heat pumps HeaMo (FGAS), so that the waste heat from the cooling process can be used as heating energy for space heating free of charge.

A major advantage is that no refrigerant is used in the installation room since the energy is transported solely via the chilled water circuit. This means that the choice of refrigerant and the refrigerant charge depends solely on the independent refrigeration system, which is usually installed outside. In addition, chillers and Multi-DENCO® close control units of the C-version can be replaced independently of one another as part of retrofit measures.

Two variants are available:

• C-Version: Chilled Water with Standard or High-Performance Heat Exchanger (4 or 6 rows)

The units are available with 3-way, 2-way or pressure-independent 2-way valves for the chilled water circuit.

• C-Version + CombiCool: Dual Chilled Water Circuits

With this system 1 indoor unit can be connected to 2 chilled water sources. The primary circuit is typically receiving chilled water (CW) from a chiller, but it can also be used in conjunction with dry coolers or similar heat reject systems for lower cost cooling or free cooling. The backup circuit is then connected to a chiller for reliability and redundancy. Either during maintenance or an unexpected fault of the primary circuit, the Multi-DENCO® unit can independently and autonomously change to the backup circuit to ensure operations can continue seamlessly. As soon as possible, the device controller automatically switches back to the primary circuit. 3-way valves are used.

Key facts

• Upflow and Downflow configurations available
• Large heat exchangers in standard or high-performance design
• Electric heating and steam humidifier as options
• Energy monitoring, automatic power transfer switch (ATS) and many other electrical options available
• Internal network solution (DENCONet) for controlling several devices in a group, as well as connection to building management systems (BMS) available
• Advanced controls package with 4.3" touchscreen
• Ideal for connection to a FläktGroup chiller with free cooling (FGFC/ GLFC series)
• Operation with water or water-glycol mixtures possible

Features

• Maximised Heat Exchanger: Very high area-specific cooling loads prevail in server rooms. Therefore, great attention is paid to the optimal design of the heat exchanger. The heat exchangers are designed in such a way that the surface area is maximised for efficient heat transfer and high cooling capacities are achieved even at higher chilled water temperatures. Servicing is done through the front doors, reducing the footprint required.
• Large EC Fans as Standard: High-quality, speed-controlled, and energy-efficient EC fans from well-known manufacturers are applied. They are installed on a slight angle to allow larger fan wheel diameters and are designed with removable frame members to make repair and replacement easier. The air flow through the indoor units and the pressure losses of the heat exchangers are optimised to achieve low fan power consumptions. The fans can be controlled according to the temperature setpoint or optionally the overpressure in a floor void or the volume flow.
• High quality control valves: A wide range of valves and actuators is available. Adaptation to all systems is possible with 3-way, 2-way and 2-way PICV valves (Pressure Independent Control Valve) and actuator options.
• Advanced controls: Each Multi-DENCO® device is equipped with a high-resolution 4.3-inch graphic display. From the home screen there is quick access to device status, temperatures in graphical form and actual and historical alarms. The control system enables an internal network solution (DENCONet) for the optimised and reliable control of several devices in a group, as well as the connection to standard building management systems (BMS). Our C5-12 control platform is designed for installations in even the most critical environments.
• CombiCool: To ensure redundancy, Multi-DENCO® can be configured with a CombiCool circuit. This means that each device can be supplied with two sources of cooling. The heat exchanger of the indoor unit then consists of two parts, i.e., two independent chilled water circuits. In the event of maintenance work or an unexpected failure of the primary circuit, the control system can independently and autonomously switch over to the backup circuit to ensure cooling continues seamlessly. As soon as possible, the device automatically switches back to the primary circuit.
• Heating & Humidification: Multi-DENCO® can be equipped with various humidification and heating options. High efficiency electrode steam humidifiers can be selected for a variety of water qualities. Additional electric heating rods can be configured for heating or re-heating in dehumidification mode, alternatively an additional 0-10 V control signal can be provided.
• Redundancy: Multiple Multi-DENCO® units in one room can be configured as a backup and redundancy scheme to meet N+1, 2N or 2(N+1) strategies. Up to 15 units can be connected using the DENCOnet software provided with each unit. Configurations such as Duty/Standby, Running Redundancy, sensor averaging, Backup 1+1 and Hot Backup are available. Groups of units that are designed as a back-up system can also distribute the capacity to several devices in normal operation, which leads to even more efficient operation due to the speed-controlled components.
• Quality Assurance: The aim of server room and data centre cooling is to prevent servers from over heating and thus from being shut down as an emergency protection. Multi-DENCO® was developed based on decades of industry and product experience. FläktGroup produces the product line in three certified factories (ISO 9001, ISO 14001). Only high-quality components from recognised quality brands are used. All devices are tested at the end of the production line by experienced quality inspectors. We offer factory tours and FAT tests (Factory Acceptance Test) - both virtual and in person.