FläktGroup
Direct Expansion Multi-DENCO®
Direct Expansion DX system for Data Centres, Server rooms and telecom rooms using a refrigerant-based system to cool the room.
Overview
Multi-DENCO® close control units are suitable for the air conditioning of server rooms, small data centres, laboratories, technical rooms, or archive rooms that have year-round air conditioning requirements. The devices offer an elevated level of flexibility, variety, efficiency and are appealing due to high-quality components such as inverter compressors, EC fans, electronic expansion valves, powerful heat exchangers and a modern control system.
• Available as Air Cooled (A-Version) & Water Cooled (W-Version)
• 7-unit sizes from 10 kW to 130 kW
• Designed for up to 100 metres of pipework separation between indoor and outdoor unit (A-version)
• Variable speed inverter compressors and electronic expansion valves (EEVs)
• Electrically Commutated (EC) fans on both indoor and outdoor units
Product description
The Multi-DENCO® product range with direct expansion is available in two versions, both with capacities from 10 to 130 kW, and including a CombiCool circuit as an option:
• A-Version: Air cooled direct expansion
Multi-DENCO® as A-version works as an air-to-air refrigeration circuit in a split design. The units are equipped with one or two evaporators with large heat transfer area, as well as powerful electrically commutated (EC) fans, inverter compressor(s) and electronic expansion valves (EEVs). Since all components are speed-controlled, Multi-DENCO® always works with precisely adapted capacity. The appropriate condenser for outdoor installation is also available, equipped with EC fans and various options, such as e.g., winter kits, heat exchanger coating or refrigerant collectors. The condenser can be installed up to 100m of pipe length from the indoor unit.
• W-Version: Water-cooled direct expansion
Based on the A-version, the W-version is combined with a WaterCool module in which the waste heat is rejected to a recooling circuit using a plate heat exchanger. The WaterCool module can be positioned on the right or left side of the Multi-DENCO® indoor unit. Alternatively, it can be located remotely and connected via refrigerant piping and control signal cables. Control valves on the water side can be configured as 3-way or pressure-independent 2-way valves for high-pressure control. The recooling circuit must be connected to an on-site recooling system. The advantages are a very small amount of refrigerant, as well as an unlimited length of pipework to the recooling system.
• CombiCool: Chilled water and direct expansion as dual circuits for either A-Version or W-Version
In addition, both systems can be configured with a CombiCool circuit for redundancy purposes. This means that each unit can be supplied with two sources of cooling. One circuit uses chilled water, e.g., from a chiller. The second circuit is the standard direct evaporator, which works with one of the versions described above (air-cooled or water-cooled). In the event of maintenance work or an unexpected failure of the chilled water circuit, the Multi-DENCO® unit automatically and autonomously switches over to the DX-system, so that the room temperature and operation are maintained seamlessly.
Key facts
• Available as Upflow and Downflow configurations
• Available as dual circuit design (CombiCool)
• Electric heating and steam humidifier as options
• Energy monitoring, power transfer switch and many other electrical options available
• Internal network solution (DENCONet) for control of several units in a group, as well as connection to building management systems (BMS) available
• Advanced controls package with 4.3" touchscreen
Features
• Inverter Compressors: All unit sizes of Multi-DENCO® are equipped with one inverter compressor, two inverter compressors or a combination of one inverter and one on/off compressor (depending on unit size). Using inverter technology, the refrigerant mass flow rate is adapted to the cooling load over a wide working range, so the refrigeration circuit is always operated at the optimum operating point with maximum efficiency. In addition, inefficient fluctuations in the supply air temperature or undershooting the setpoint are avoided.
• Large EC Fans as Standard: High-quality, speed-controlled, and energy-efficient EC fans from well-known manufacturers are applied. They are installed on a slight angle to allow larger fan wheel diameters and are designed with removable frame members to make repair and replacement easier. The air flow through the indoor units and the pressure losses of the heat exchangers are optimised to achieve low fan power consumptions. The fans can be controlled according to the temperature setpoint or optionally the overpressure in a floor void or the volume flow.
• Advanced Controls: Each Multi-DENCO device is equipped with a high-resolution 4.3-inch graphic display. From the home screen there is quick access to device status, temperatures in graphical form and actual and historical alarms. The control system enables an internal network solution (DENCONet) for the optimised and reliable control of several devices in a group, as well as the connection to standard building management systems (BMS). Our C5-12 control platform is designed for installations in even the most critical environments.
• CombiCool: To ensure redundancy, Multi-DENCO® can be configured with a CombiCool circuit. This means that each device can be supplied with two sources of cooling. The heat exchanger of the indoor unit then consists of two parts, the standard direct expansion evaporator, and an additional chilled water cooler. The chilled water circuit can, for example, be supplied by a chiller or chiller with free cooling function (FläktGroup FGFC/GLFC). In the event of maintenance work or an unexpected failure of the chilled water circuit, the Multi-DENCO® unit automatically and autonomously switches over to the DX-system, so that the room temperature and cooling operation are maintained seamlessly.
• Commissioning Ports: Multi-DENCO® indoor units are equipped with innovative commissioning connections for the refrigeration cycle. These allow commissioning and service technicians quick and easy access at a convenient central location. The connections are located directly behind the front door and allow connection to three different points in the refrigerant circuit for charging and pressure testing.
• Heating & Humidification: Multi-DENCO® can be equipped with various humidification and heating options. High efficiency electrode steam humidifiers can be selected for a variety of water qualities. Additional electric heating rods can be configured for heating or re-heating in dehumidification mode, alternatively an additional 0-10 V control signal can be provided.
• Redundancy: Multiple Multi-DENCO® units in one room can be configured as a backup and redundancy scheme to meet N+1, 2N or 2(N+1) strategies. Up to 15 units can be connected using the DENCOnet software provided with each unit. Configurations such as Duty/Standby, Running Redundancy, sensor averaging, Backup 1+1 and Hot Backup are available. Groups of units that are designed as a back-up system can also distribute the capacity to several devices in normal operation, which leads to even more efficient operation due to the speed-controlled components.
• Quality Assurance: The aim of server room and data centre cooling is to prevent servers from overheating and thus from being shut down as an emergency protection. Multi-DENCO® was developed based on decades of industry and product experience. FläktGroup produces the product line in three certified factories (ISO 9001, ISO 14001). Only high-quality components from recognised quality brands are used. All devices are tested at the end of the production line by experienced quality inspectors. We offer factory tours and FAT tests (Factory Acceptance Test) - both virtual and in person.