Östberg
HERU S EC
HERU S EC, energy recovery units with side connections.
Overview
HERU S EC, energy recovery units with side connections.
Key facts
• Models: HERU 100 S EC, HERU 160 S EC, HERU 200 S EC, HERU 300 S EC
• Voltage: 230 V
• Phase: 1 / 2~
• Frequency: 50 Hz
• Power: 1420–2890 W
• Power, fans: 200–573 W
• Power, heater: 1200–2300 W
• Current: 7–14.5 A
• Current, fans: 1.64–4.4 A
• Current, heater: 5.22–10 A
• Speed: 2820–3020 r.p.m.
• Sound pressure level at 3 m: 38–43 dB(A)
• Weight: 59–105 kg
• Weight (empty casing): 30.6–54.3 kg
• Enclosure class: IP41
• Duct connection: 160 / 200 / 250 mm
• Max. flow @ 0Pa: 121–331 l/s
• Max. pressure: 731–797 Pa
• Voltage range: 220-240 V
Features
• NEW! Controlled by the HERU IQ app via Bluetooth or cloud service (use of Cloud service requires internet connection to the HERU).
• Wireless touch display as accessory.
• Model with side connections.
• Designed for supply and extract air ventilation with energy recovery.
• Suitable for installation in apartments, small houses, offices and other premises where there are stringent requirements on the indoor environment.
• High temperature efficiency, low energy consumption (SFP), low sound level, high operating reliability and provides clean indoor air.
• Unique design minimises all thermal bridges.
• Integrated Modbus communication. No accessories needed.
• Easy installation wizard.
• Scheduled operation.
• Integrated control for preheater.
• Supports use of presence sensors.
• Airflow is generated by two silent radial fans with EC motors and impellers with backward curved blades.
• The fans are connected using quick connectors and are very easy to remove for cleaning.
• A regenerative, non hygroscopic, aluminium rotating heat exchanger located in the centre of the unit. The heat exchanger can easily be removed for cleaning.
• Delivered with bag filter ISO ePM1 65% as standard, for both exhaust and supply air. The filters are very easy to change.
• Integrated controls for heating/cooling. Increases thermal comfort by heat recovery or night cooling.
• Integrated electric heater.
• The unit is made of galvanised steel sheet.
• 50 mm insulation.
• For placement in warm or cold areas.
• Comes in right-hand design as standard, but can easily be rebuilt to left-hand design.
• Can be installed with the lid upwards or to the side.
• HERU 100S and HERU 160S are equipped with wall plug. HERU 200S and HERU 300S comes with cable for fixed installation.