/

Clean Room

/

Clean Room Filtration Units

/

Fresh Heaven MAXX O Laminar Airflow Unit
Fresh Heaven MAXX O Laminar Airflow Unit
Fresh Heaven MAXX O Laminar Airflow Unit

FläktGroup

Fresh Heaven MAXX O Laminar Airflow Unit

This laminar airflow unit ensures full filtration of air supplied by an air-handling unit and protects the operating area around a patient.

Overview

Fresh Heaven MAXX O ensures full filtration of air supplied by an air-handling unit protecting the operating theater area around a patient.

• Complete filtration of operating area
• Easy installation, maintenance and disinfection
• Low initial pressure drop of HEPA filters
• Tailored dimensions with LED lighting and control unit

Product description

The Fresh Heaven MAXX O laminar air-flow units are part of the structural arrangement of the suspended ceiling of an operating theater.

Fresh Heaven MAXX O unit supplies clean air in a low-turbulent and vertical flow into an operating room. Thus, the contamination of sensitive areas and equipment can be held at a minimised level.

AHU supplies pre-treated air through rectangular inlets into the pressure chamber with filters. Clean air flows out of a laminarizer stretched across an aluminium frame into the operating theater, forming the protection zone. Contaminated air is extracted via extract-air grilles into AHU.

Fresh Heaven MAXX O unit design provides space in the centre for surgical lighting installation. The laminarizer's circumference is lit by LED lighting integrated into the casing's sides. To enhance laminar airflow and minimise air turbulence, a PET-G soft wall can be integrated around the entire circumference of the unit.

There are available 8 sizes, and an air volume is given at a velocity of 0.30 m/s:

• A – 320 x 320 x 45 cm, air volume 11 060 m3/h
• B – 300 x 300 x 45 cm, air volume 9 720 m3/h
• C – 300 x 240 x 45 cm, air volume 7 780 m3/h
• D – 300 x 200 x 45 cm, air volume 6 480 m3/h
• E – 240 x 240 x 45 cm, air volume 6 220 m3/h
• F – 240 x 180 x 45 cm, air volume 4 670 m3/h
• Y – 183 x 180 x 45 cm, air volume 3 560 m3/h (without a central passage for an operating lamp)
• Z – 183 x 123 x 45 cm, air volume 2 430 m3/h (without a central passage for an operating lamp)

Filters offer includes HEPA filters in an aluminium frame 104 mm high. The filter features a gel gasket and protective grid on its clean air side. The filters are available in following filtration classes:

• H13
• H14

Casing:

• Varnished steel RAL 9010
• Stainless steel V2A ~AISI304

Outlets:

• Single-layer PES (polyester) fabric
• Double-layer with differential airflow (higher air velocity in the central area, measuring 100 x 200 cm)
• Perforated steel painted RAL 9010
• Perforated stainless steel, electropolished

Selectable accessories:

• Differential-pressure switch – monitors differential pressure of filters (pressure connection via two plastic tubes), can be equipped with connections to a filter-exchange indicator
• Filter-exchange indicator – may be installed in the central passage of the low-turbulence flow unit to signal filter clogging via red LED
• Lighting- LED lighting can be installed around the entire perimeter of the laminar air-flow field
• Border soft wall as PET-G screen - to minimise air turbulences, maximise laminar air-flow zone and prevent reduction in its cross-section - a soft wall (curtain) can be integrated on the entire circumference of the unit. Standard width 30 cm.

Key facts

• Air flow speed 0.18 - 0.38 m/s
• Dimensions 1.83 m x 1.23 m (min.) and 3.20 m x 3.20 m (max.)
• 8 model sizes
• Central passage for mounting surgical lighting
• Operating mode: air supplied by AHU
• Casing material in varnished steel sheet RAL 9010 or stainless steel sheet V2A / AISI 304
• Filter seal as gel-type
• Outlets as single-layer laminarizer or double-layer laminarizer (for differential air flow) in PES fabric on aluminium frame

Features

• Unit casing: The unit casing, featuring independent suspension, stands at a height of 450 mm and is designed as a pressure chamber in stainless steel V2A (AISI 304) or varnished steel RAL 9010. Resistant to disinfectants and mechanical damage, the casing is easy to clean.
• Laminarizer: To create laminar airflow, either a single-layer polyester fabric (PES) or a double-layer outlet is utilised. The double-layer outlet employs a differential airflow with higher air velocity in the central area, measuring 100 x 200 cm.
• UV-C lamps: Decrease the spread of airborne pathogens such as virus and bacteria with the proven and effective UV-C modules.
• LED lighting: LED lighting can be installed around the entire perimeter of the laminar air-flow field. Different colours can signal working mode of operating theater or laminar ceiling (e.g. standard white colour is used for day mode, red for night/reduced mode).
• Filters: Full-area filtration is ensured with fluid-gasket filters of class H13 or H14. Filter frame is made of extruded aluminium, while the filter media is protected against damages by a steel epoxy varnished mesh mounted on the clean-air side.